AboutNewsProductsDocumentationInquiries
Search:
AnalyzersCalibratorsTest BenchesFlow Meters
   Moisture-in-Gas   Flue Gas   LAND   Sulfur   Spectrophotometer   Mass Spectrometer   Software

Sulfur removal from oil or natural gas is an integral part of different processes.
It is used to obtain high quality products in oil refining and gas processing as well as in order to meet the environmental protection requirements.

We offer reliable photometric analyzers measuring H2S and SO2 to be used at sulfur removal and recovery plants as well as in the process control systems of other plants processing hydrocarbons.

880-NSL/900 ADA

Brochure | Order List
Analizer 880-NSL/900 ADA
Process photometric analyzer for Claus process and sulfur pit

Designed as 2Expymde[ib]IICT3 X field unit with controller functions, mounted directly on process pipe (880-NSL) or on sulfur pit roof (881) as well as separate probe and field unit (900 ADA)
Ranges Accuracy
H2S 0...2% ±2% of full scale
SO2 0...1% ±2% of full scale
Excess H2S ±1% ±0.2%

900 ADA 1ExpydIIBT3 X explosion proof version available



933

Brochure | Order List
Analizer 933
Process photometric sulfur-in-natural-gas analyzer

Designed as 1ExdIIBT3 X explosion proof field unit with controller functions
Ranges Accuracy
H2S from 0...5 ppmv to 0...1000 ppmv ±0.25 ppmv
COS from 0...50 ppmv to 0...1000 ppmv ±2.5 ppmv
MeSH from 0...50 ppmv to 0...1000 ppmv ±2.5 ppmv

 



931/932

Brochure | Order List
Analizer 931/932
Process photometric analyzers

Designed as 1ExdIIBT3 X explosion proof field unit with controller functions
Ranges Accuracy
H2S from 0...4000ppm to 0...100% 1% of full scale

Other components available depending on application



909/910/919/920/921/922

No navigation record for 910_920 model!
Analizer 909/910/919/920/921/922
Process photometric multi-purpose analyzers

Designed as a field unit and separate controller
Ranges Accuracy
H2S from 0...5 ppmv to 0...100% ±3% of full scale
SO2 from 0...500 ppmv to 0...100% ±3% of full scale

1ExpydIIBT3 X explosion proof version available

* For similar application in power industry we offer non-explosion proof CEM LAND analyzers


4000 family

Brochure | Order List
Analizer 4600/4700/920
Process photometric multi-purpose analyzers

Designed as 1ExpIT3 X field unit with controller functions or as 19" rack mount analyzer
Ranges Accuracy
H2S from 0...5 ppmv to 0...100% ±3% of full scale
SO2 from 0...500 ppmv to 0...100% ±3% of full scale

Explosion proof version available

 


 Copyright © 2001—2010 "Artvik"
 info@artvik.com