Home >Products >Calibrators >Multifunction Calibrators

Multifunction Calibrators

Beamex MC6-T, version "-R" multifunction calibrator and communicator with built-in dry-block
Models
MC6-T150 (-R)
MC6-T660 (-R)
Calibrator, multichannel data logger as well as HART, Foundation Fieldbus H1, Profibus PA communicator in one portable instrument
V, mV, mA, Ohm, Hz, pulse measurement and generation, accuracy up to ±0.007%
Temperature range of -30 ... 660°C, accuracy up to ±0,04°C
Measurement and simulation of TC and RTD signals complying with GOST, IEC, DIN temperature curves as well as user defined ones
Pressure measurement in the range of -0.1...100 MPa, accuracy up to ±0.015% FS
Documenting capability using Beamex CMX software (Russian version available) and Beamex LOGiCAL cloud-based software
See more
As we are targeted to the CIS market please visit here the corresponding product page in Russian for detailed product information.
Not supplied temporarily to the Russian Federation and the Republic of Belarus
Multifunction Intrinsically Safe Calibrator and Communicator Beamex MC6-Ex, version “-R”
0Ex ia IIC T4 Ga X intrinsically safe marking
Calibrator, multichannel data logger and HART, Foundation Fieldbus H1, Profibus PA communicator in one instrument
V, mV, mA, Ohm, Hz, pulse measurement and generation, accuracy up to ±0.007%
Measurement and simulation of TC and RTD signals, complying with GOST, IEC, DIN temperature curves as well as user defined ones
Pressure measurement in the range of -0.1...100 MPa, accuracy up to ±0.015% FS
Large color touch screen, user interface in Russian
Documenting capability using Beamex CMX software (Russian version available)
See more
As we are targeted to the CIS market please visit here the corresponding product page in Russian for detailed product information.
Not supplied temporarily to the Russian Federation and the Republic of Belarus
Multifunction Calibrator and Communicator Beamex MC6, version “-R”
Calibrator, multichannel data logger and HART, Foundation Fieldbus H1, Profibus PA communicator in one instrument
V, mV, mA, Ohm, Hz, pulse measurement and generation, accuracy up to ±0.007% FS
Measurement and simulation of TC and RTD signals, complying with GOST, IEC, DIN temperature curves as well as user defined ones
Pressure measurement in the range of -0.1...100 MPa, accuracy up to ±0.015% FS
Large color touch screen, user interface in Russian
Documenting capability using Beamex CMX software (Russian version available)
See more
As we are targeted to the CIS market please visit here the corresponding product page in Russian for detailed product information.
Not supplied temporarily to the Russian Federation and the Republic of Belarus
Beamex MC4-R Multifunction Calibrator
V, mV, mA, Ohm, Hz, pulse measurement and generation, accuracy up to ±0.02% FS
Measurement and simulation TC and RTD signals, complying with GOST, IEC, DIN temperature curves as well as user defined ones
Pressure measurement in the range of -0.1...100 MPa, accuracy up to ±0.015% FS
Graphic screen, user interface in Russian
Documenting capability using Beamex СМX calibration software (Russian version available)
See more
As we are targeted to the CIS market please visit here the corresponding product page in Russian for detailed product information.
Not supplied temporarily to the Russian Federation and the Republic of Belarus
Beamex MC2-R Multifunction Calibrator
V, mV, mA, Ohm, Hz, pulse measurement and generation, accuracy up to ±0.02% FS
Measurement and simulation TC and RTD signals, complying with GOST, IEC, DIN temperature curves as well as user defined ones
Pressure measurement in the range of -0.1...100 MPa, accuracy up to ±0.015% FS
Graphic screen, user interface in Russian
See more
As we are targeted to the CIS market please visit here the corresponding product page in Russian for detailed product information.
Not supplied temporarily to the Russian Federation and the Republic of Belarus
Portable electrical signal calibrator with pressure measurement capability ASC-400-R
V, mV, mA, Ohm, Hz, pulse measurement and generation, accuracy up to ±0.01% RDG
TC and RTD measurement and simulation complying with GOST, IEC, DIN temperature curves as well as user defined ones
Pressure measurement in the range of -0.1...100 MPa, accuracy up to ±0.025% RDG
High pressure CPF quick-connect fittings (up to 70 MPa) as default
See more
As we are targeted to the CIS market please visit here the corresponding product page in Russian for detailed product information.
Not supplied temporarily to the Russian Federation and the Republic of Belarus
Artvik